Datasheet
108-98011 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 11 of 13
Telecom-, Signal and RF Relays
Reed V23100-V4 Relay
AXICOM
Type of relay DIP version SIL version Mini SIL Version
Type of contact/s 1 form a 2 form a 1 form c 1 form a 1 form a
Contact material Ruthenium
Maximum continuous current 1 A 1.2 A 1 A 1 A
Maximum switching current 0.5 A 0.25 A 0.5 A 0.5 A
Maximum switching voltage
at nominal voltage: 5 Vdc
12-24 Vdc
200 Vdc / Vac peak
200 Vdc / Vac peak
175 Vdc
175 Vdc peak
200 Vdc / Vac
200 Vdc / Vac
200 Vdc / Vac peak
200 Vdc / Vac peak
Maximum switching capacity
DC voltage
AC voltage
10 W
10 VA
3 W
3 VA
10 W
10 VA
10 W
10 VA
Initial contact resistance /
measuring condition: <150 mΩ
Electrical endurance at 12 V / 10 mA
at 24 V / 400 mA
5 x 10
7
5 x 10
6
Type of relay DIP version SIL version Mini SIL Version
Type of contact/s 1 form a 2 form a 1 form c 1 form a 1 form a
Maximum operate time (including bounce) 0.75 ms 1.1 ms 0.75 ms 0.75 ms
Maximum release time 0.15 ms 1.6 ms 0.15 ms 0.15 ms
Operating temperature range -40 °C ... +85 °C
Storage temperature -40 °C ... + 95 °C
Thermal resistance Approx. 75 K / W
Maximum permissible coil temperature 105 °C
Vibration resistance (function) 30 G
10 to 2000 Hz
30 G
50 to 2000 Hz
30 G
10 to 2000 Hz
30 G
10 to 2000 Hz
Shock resistance, half sinus, 11 ms 150 G 50 G 150 G 50 G
Degree of protection immersion cleanable, IP 67
Mounting position any
Resistance to soldering heat 265 °C / 10 s
Insulation resistance at 500 Vdc contact coil > 10
9
Ω
Dielectric test voltage (1 min)
contact / coil
contact / contact
1500 Vdc
250 Vdc
1500 Vdc
200 Vdc
1500 Vdc
250 Vdc
1500 Vdc
225 Vdc
Capacitance
between coil and contacts
between adjacent contact sets
between open contacts
max. 2 pF
max. 1 pF
max. 1 pF
Contact Data
General Data
Insulation
High Frequency Data