3.2. Locking Lance Reset (See Figure 3)
Check compatibility of the contact and tool, then
proceed as follows:
Wires
Back of
Housing
Tip of Tool
Window
Extraction
1. Orient the lance reset portion so that the taper
is facing the contact locking lance.
Figure 2
Side View
Top View
Reset Locking Lance
Lance Reset
Portion
Contact Locking
Lance
Lance Reset Portion
Contact Locking Lance
Figure 3
2. Keep the lance reset portion against the
contact and slide it towards the base of the
contact locking lance until it bottom
3. Remove the tool. The contact is ready for
re-insertion into the housing.s.
NOTE
i
Damaged contacts should not be used. If a
damaged contact is evident, it should be cut from
the wire and rep
laced with a new one.
4. MAINTENANCE AND INSPECTION
The tool should conform to the dimensions provided in
Figure . It is recommended that each tool be
inspected
upon arrival to be sure it has not been damaged in
tra
nsit and at regularly scheduled intervals to be sure it
remains functional.
Keep the tool clean.
5. REVISION SUMMMARUY
Since the previous release of this instruction sheet,
the new company logo has been applied