Datasheet
Mini- Universal MATE- N- LOK Splash- Proof Sealed Connectors
114- 13089
Rev B 9 of 20Tyco Electronics Corporation
Figure 7
Up and Down Alignment
Side- to- Side Alignment
Datum Line
Datum Line
4_ Max
4_ Max
4_ Max
4_ Max
Note: Socket Contact Shown, Requirements
A
pply Equally to Pin Contact
3.7. Interface Seal
The interface seal must be installed onto the plug housing. The installed interface seal must fit inside the
channel at the base of the silos of the plug housing. The interface seal must remain flat against the back of the
channel and shall not be twisted. There shall be no tears, rips, or other damage to the interface seal. Refer to
Figure 8.
A method to prevent damage to the interface seal is to use the mating cap housing (without contacts) or pin header
(not installed onto pc board) to slide the interface seal along the silos and against the back of the channel.
3.8. Installing Contacts into Housing
The contacts must be installed into the plug housing and cap housing. Each contact must be inserted into a
contact cavity at the wire end of the housing until it bottoms (there should be an audible “click”). For optimum
sealing performance, the wire seal on the contact must have at least two of the three flanges fully inserted into
the contact cavity. Each contact must be locked into place. Refer to Figure 8.
Because of the wire seal, these contacts require more insertion force than unsealed contacts (without a wire seal).
3.9. Cavity Plug Seal
The cavity plug seal must be installed into any unused contact cavities of the plug housing and cap housing.
The cavity plug seal must be inserted (short tab end first) into the contact cavity at the wire end of the housing.
For optimum sealing performance, the cavity plug seal must have at least two of the three flanges fully inserted
into the contact cavity. See Figure 8.
A cavity plug seal must also be installed in any mating contact cavity containing a keying plug. See Figure 8.
The cavity plug seals can be installed manually or by using Insertion Tool 91002--1. Instruction for using the tool is
provided on Instruction Sheet 408--7347.
3.10. Keying Plug
The keying plug must be installed into an empty contact cavity in the plug housing or cap housing. The keying
plug must be inserted (tapered end first) into the contact cavity at the mating face of the housing until it
bottoms (there should be an audible “click”).
NOTE
i
NOTE
i
NOTE
i