6. VISUAL AID
The illustration below shows a typical application of .110, .187, .250, .312, and .375 Series FASTIN-FASTON
housings and contacts. This illustration should be used by production personnel to ensure a correctly applied
product. Applications which DO NOT appear correct should be inspected using the information in the preceding
pages of this specification and in the instructional material shipped with the product or tooling.
FIGURE 9. VISUAL AID
HOUSING MUST NOT BE
DAMAGED IN ANY WAY
ALL CONTACTS MUST BE
FULLY SEATED IN HOUSING
LOCKING LANCE
MUST NOT BE BENT
LOCKING LANCE
MUST NOT BE BENT
FRONT AND REAR
BELLMOUTHS
SHALL BE EVIDENT
WIRE BARREL SEAM MUST BE
CLOSED WITH NO EVIDENCE OF
LOOSE WIRE STRANDS
WIRE CONDUCTORS AND
INSULATION MUST BE VISIBLE
IN TRANSITION AREA
(BETWEEN WIRE BARREL
AND INSULATION BARREL)
CONDUCTORS MAY EXTEND
BEYOND WIRE BARREL TO
MAXIMUM ALLOWED
THERE MUST BE NO DAMAGE
TO MATING END
THERE MUST BE NO
DAMAGE TO WIRE
INSULATION BARREL MUST NOT
CUT INTO WIRE INSULATION
ALL CONTACTS MUST BE
FULLY SEATED IN HOUSING
POLARIZATION FEATURES
MUST BE ALIGNED
BEFORE MATING
INSULATION BARREL MUST
HAVE “F” CRIMP (SHOWN)
OR OVERLAP CRIMP