Datasheet
114-2025
6 of 9
Rev F
Figure 6
3.7. Panel
The .187 and .250 Series receptacle housings that can be mounted to a panel, hardware, and related panel
cutout dimensions are given in Figure 7.
3.8. Mating
The polarization features of the plug housing and receptacle housing must be aligned before pushing the
housings together.
Figure 7 (Cont’d)
.250 SERIES
RECEPTACLE
HOUSING SIZE
PANEL DIMENSION
ABCDEFGHJ
4
2.31
[.091]
—
29.77
[1.172]
15.88
[.625]
—
25.15
[.990]
6.73
[.265]
28.58
[1.125]
6.35
[.250]
6
3.43
[.135]
3.56
[.140]
35.86
[1.412]
14.22
[.560]
15.88
[.625]
29.01
[1.142]
04.7
[.185]
34.42
[1.355]
3.96
[.156]
8
4.39
[.173]
06.1
[.240]
47.52
[1.871]
16.76
[.660]
18.42
[.725]
38.74
[1.525]
06.6
[.260]
46.23
[1.820]
6.35
[.250]
Tab Contact
Locking Lance
Contact Cavity
Contact Fully Seated
in Plug Housing
Wire End of
Plug Housing
Wire End of
Receptacle Housing
Receptacle Contact
Locking Lance
Contact Cavity
Contact Fully Seated
in Plug Housing
C
B
A Ref
G
D
E
1.4 [.055]
Max
Hole Diameter
for No. 6
Screw
F
1.4 [.055]
Max
4.37
[.172]
H
J
Alternate Panel Cutout
Panel Cutout for .250 Series Receptacle Housing