Datasheet
501-45
Rev B 6 of 8
F. Thermal Shock - Test Group 2|
No evidence of physical damage was visible as a result of thermal shock testing.|
G. Humidity/temperature Cycling - Test Group 2|
No evidence of physical damage was visible as a result of humidity/temperature cycling.|
H. Mixed Flowing Gas - Test Group 4|
No evidence of physical damage was visible as a result of exposure to the pollutants of mixed|
flowing gas.|
I. Temperature Life (Preconditioning) - Test Groups 3 and 4|
No evidence of physical damage was visible as a result of exposure to elevated temperature.|
J. Temperature Life - Test Group 1|
No evidence of physical damage was visible as a result of exposure to elevated temperature.|
K. Thermal Disturbance - Test Group 4|
No evidence of physical damage was visible as a result of thermal disturbance testing.|
3. TEST METHODS
3.1. Test Report CTL5730-115-016|
A. Examination of Product
Product drawings and inspection plans were used to examine the specimens. They were examined
visually and functionally.
B. Termination Resistance, Dry Circuit
Termination resistance measurements at low level current were made using a 4 terminal
measuring technique. The test current was maintained at 100 milliamperes DC with an open circuit
voltage of 50 millivolts DC.
C. Dielectric Withstanding Voltage
A test potential of 1000 volts DC was applied between adjacent contacts. This potential was
applied for 1 minute and then returned to zero.
D. Insulation Resistance
Insulation resistance was measured between adjacent contacts using a test voltage of 500 volts
DC. This voltage was applied for 1 minute before the resistance was measured.