Datasheet

501-45
Rev B 5 of 8
H. Connector Unmating Force - Test Group 1
All unmating force measurements were greater than 1.5 ounces per contact.
I. Durability - Test Group 1
No evidence of physical damage was visible as a result of mating and unmating the specimens 75
times for 15 microinches of gold plating and 150 times for 30 microinches of gold plating.
J. Thermal Shock - Test Group 4
No evidence of physical damage was visible as a result of thermal shock testing.
K. Humidity/temperature Cycling - Test Group 4
No evidence of physical damage was visible as a result of humidity/temperature cycling.
L. Mixed Flowing Gas - Test Group 3
No evidence of physical damage was visible as a result of exposure to the pollutants of mixed
flowing gas.
M. Temperature Life - Test Group 2
No evidence of physical damage was visible as a result of exposure to elevated temperature.
2.2. Test Report EA20080505T|
A. LLCR - Test Groups 1, 2, 3, 4 and 7|
All LLCR measurements, taken at 100 milliamperes maximum and 20 millivolts maximum open|
circuit voltage were less than 15 milliohms. All wire bulk was removed from the measurements.|
B. Random Vibration - Test Group 3|
No discontinuities were detected during vibration testing. Following vibration testing, no cracks,|
breaks, or loose parts on the specimens were visible.|
C. Durability (Preconditioning) - Test Groups 1, 2, 3 and 4|
No evidence of physical damage was visible as a result of mating and unmating the specimens 20|
times at a maximum rate of 300 cycles per hour.|
D. Durability - Test Group 7|
No evidence of physical damage was visible as a result of mating and unmating the specimens 75|
times for 3 microinches of gold flash over 12 microinches of palladium/nickel plating and 150 times|
for 3 microinches of gold flash over 27 microinches of palladium/nickel plating.|
E. Reseating - Test Groups 1, 2 and 4|
No evidence of physical damage was visible as a result of mating and unmating the specimens 3|
times.|