1.5. Test Specimens
Test specimens were representative of normal production lots. Specimens identified with the following
part numbers were used for test:
Test Group Quantity Part Number Description
Test Report CTL5730-115-016
1,2,3,4 5 each 746288-9 40 position 30 μin Au receptacle
1,2,3
5 each 499997-9 40 position 15 μin Au receptacle
5 each 103308-8 15 μin Au header
5 each 104339-8 30 μin Au header
Test Report EA20080505T|
1,2,3,4,7|
25 each| 5104340-8|3 μin Au flash over 12 μin Pd/Ni header|
|
25 each| 104340-7| 15 μin Au header|
|
25 each| 103309-7| 30 μin Au header|
|
25 each| 5103309-8|3 μin Au flash over 27 μin Pd/Ni header|
|
25 each| 2057173-1|3 μin Au flash over 12 μin Pd/Ni receptacle|
|
25 each| 2057174-1|3 μin Au flash over 12 μin Pd/Ni receptacle|
|
25 each| 2057175-1|3 μin Au flash over 27 μin Pd/Ni receptacle|
|
25 each| 2057176-1|3 μin Au flash over 27 μin Pd/Ni receptacle|
Figure 1
1.6. Environmental Conditions
Unless otherwise stated, the following environmental conditions prevailed during testing:
! Temperature: 15 to 35°C
! Relative Humidity: 20 to 80%