Data Sheet

108-20090
Rev. C1
Page 6 of 14
LOC I
FTEC174 rev. 1 July 99
FEATURES TEST CONDITIONS LIMITS
3.12
Water resistance:
Static immersion
Mated connectors subjected to 5
cycles composed of:
- 30 min. in oven at +125°C
- 30 min. immersed in water with
5% of NaCl under a pressure of
0,01bar at a temperature of 23°C
-Insulation resistance: ≥200MΩ
-No leakage detected to a
visual examination
3.13
Water resistance:
Dynamic immersion
Mated connectors immersed in
water with 5% on NaCl, under a
pressure of 0,01bar at a
temperature of 23°C.
Wire pulled with a force of
1,5÷2,5N oscillated 100.000
times (as per Fig. 2).
Oscillation frequency:
50cycles/min.
-Insulation resistance: ≥200MΩ
-No leakage detected to a
visual examination
3.14
Water resistance:
IP X6K Test
Test according to DIN 40050,
Part 9.
Duration: 3min. minimum
Subject mated connectors
completely loaded with terminals
to water jet with following
parameters:
nozzle:6.3mm dia
pressure: 1000kPa
(test setup as per Fig. 4)
-Insulation resistance as above
specified.
-No leakage detected to a
visual examination
3.15
Water resistance:
IP X9K Test
Test according to DIN 40050,
Part 9.
Duration: 30s for each nozzle.
Subject mated connectors
completely loaded with terminals
to the cumulative action of the
four nozzles.
(test setup as per Fig. 5)
-Insulation resistance and
dielectric withstanding voltage
as above specified.
-No leakage detected to a
visual examination