Data Sheet
108-20090
Rev. C1 
Page 6 of 14
LOC I
FTEC174 rev. 1 July 99 
FEATURES  TEST CONDITIONS  LIMITS 
3.12 
Water resistance: 
Static immersion 
Mated connectors subjected to 5 
cycles composed of: 
- 30 min. in oven at +125°C 
- 30 min. immersed in water with 
 5% of NaCl under a pressure of 
0,01bar at a temperature of 23°C 
-Insulation resistance: ≥200MΩ 
-No leakage detected to a 
 visual examination 
3.13 
Water resistance: 
Dynamic immersion 
Mated connectors immersed in 
water with 5% on NaCl, under a 
pressure of 0,01bar at a 
temperature of 23°C. 
Wire pulled with a force of 
1,5÷2,5N oscillated 100.000 
times (as per Fig. 2). 
Oscillation frequency: 
50cycles/min. 
-Insulation resistance: ≥200MΩ 
-No leakage detected to a 
 visual examination 
3.14 
Water resistance: 
IP X6K Test 
Test according to DIN 40050, 
Part 9. 
Duration: 3min. minimum 
Subject mated connectors 
completely loaded with terminals 
to water jet with following 
parameters: 
nozzle:6.3mm dia 
pressure: 1000kPa 
(test setup as per Fig. 4) 
-Insulation resistance as above 
specified. 
-No leakage detected to a 
 visual examination 
3.15 
Water resistance: 
IP X9K Test 
Test according to DIN 40050, 
Part 9. 
Duration: 30s for each nozzle. 
Subject mated connectors 
completely loaded with terminals 
to the cumulative action of the 
four nozzles. 
(test setup as per Fig. 5) 
-Insulation resistance and 
dielectric withstanding voltage 
as above specified. 
-No leakage detected to a 
 visual examination 