Data Sheet

108-20090
Rev. C1
Page 4 of 14
LOC I
FTEC174 rev. 1 July 99
3.0 TEST REQUIREMENTS AND PROCEDURES SUMMARY:
FEATURES TEST CONDITIONS LIMITS
3.1
Voltage Drop
(mated connectors)
Between two points on wires at
1cm from the housing edges.
Test currents:
6A for 0,5sqmm wire
11A for 1,0sqmm wire
14A for 1,5sqmm wire
3 mV/A on new contacts.
The voltage drop of wire must
be subtracted
3.2
Contact resistance
(mated contacts)
Between the ends of crimps.
Test current: 10mA
3 mΩ on new contacts.
3.3
Insulation Resistance
(mated connectors)
Between adjacent contacts apply
500 Vd.c. for 1 min.
200 M
(new contacts)
3.4
Dielectric withstanding
voltage
Between adjacent contacts apply
1500Va.c. for 1 min.
No breakdown or flashes
3.5
Connector mating force
Mate connectors with their
contacts loaded at a speed of
25÷100mm/min
1 pos. conn.:
≤ 80N
2÷6 pos. conn.:
≤ 120N
3.6
Connector unmating
force
Unmate connectors with their
contacts loaded at a speed of
25÷100mm/min:
a) Without operate the locking
lance
b) Operating the locking lance
a) All positions:
≥ 145N
b) 1 pos. conn.:
≤ 80N
2÷6 pos. conn.:
≤ 120N