Data Sheet

ZPSA40 & 60 Series
1
ZPSA40 & 60 Series
Key Market Segments & Applications
Video/Audio Routers
Datacom
Point of Sale
Test and Measurement
LED Signs
• Wide Range AC Input
• Low Profile, Industry Standard Footprint
• Global Safety Agency Compliance
• RoHS Compliant
ZPSA40 & 60 Features and Benefits
Features Benefits
• Industry Standard Footprint Available to Second Source
• Up to 88% efficiency • Less System Heating
• Broad Product Range • Optimization of Power Supply to System
• Meets EN61000-4 Immunity • Greater Reliability
MODEL ZPSA40 ZPSA60
ITEMS
Input Voltage range - 90 - 264VAC (47 - 440Hz) or 120 - 370VDC
Inrush Current (132/265VAC) A 25 / 50
Input Current (115/230VAC) A < 1.2A < 1.4A
Leakage Current mA 0.8mA max (264VAC, 60Hz)
Temperature Coefficient - ±0.05%/°C
Voltage Accuracy - ±1%
Minimum Load A None
Load Regulation - ±1%
Line Regulation - ±0.5%
Ripple & Noise (1) mV 1% or 50mV whichever is greater
Short Circuit Protection - Continuous - hiccup mode
Overvoltage Protection V Typically 110-130% of nominal
Hold Up Time (Typ) ms 8ms at 115VAC input
LED Indicator - Green LED = OK
Operating Temperature 0 to +70°C with derating
Storage Temperature - -20 to +85°C
Humidity (non condensing) - 10 - 95% RH
Cooling - Convection
Withstand Voltage Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance >100MΩ at 25C & 70%RH, Output to Ground 500VDC
Vibration (non operating) 23.52m/s
2
(10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
Shock - < 196.1 m/s
2
(20G)
Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1 Class I, CE Mark (LVD)
Conducted & Radiated EMI - EN55022-B, FCC Class B
Immunity - EN61000-4-2,-3,-4,-5,-6,-8
Weight (Typ) g 130g
Size (WxLxH) mm 101.6 X 50.8 X 27.1 (including underside components )
Warranty yrs 2
Specifications
2" x 4" 40W to 60W
AC-DC Power Supplies
Notes: (1) Measured with 0.1µF ceramic & 10µF electrolytic at 20MHz BW

Summary of content (4 pages)