ZPSA100 Series
Features
PFC
Wide Range AC Input
Low Profi le, Industry Standard Footprint
Global Safety Agency Compliance
RoHS Compliant
Up to 84% effi ciency
Meets EN61000-4 Immunity
3” x 5” 100W AC-DC Power Supplies
Model ZPSA100
Input Voltage range - 90 - 264VAC (47 - 440Hz) or 120 - 370VDC*
Inrush Current A 25 / 50 (cold start)
Input Current (115/230VAC) A 1.1 / 0.6
Temperature Coeffi cient - ±0.05%/°C
Voltage Accuracy - ±1%
Minimum Load A None
Load Regulation - ±1%
Line Regulation - ±0.5%
Ripple & Noise (1) mV 5V: 2%, others 1%
Short Circuit Protection - Foldback
Overvoltage Protection V Typically 110-130% of nominal, auto recovery
Hold Up Time (Typ) ms 16ms at 115VAC input
LED Indicator - Green LED = OK
Operating Temperature °C 0 to +70°C with derating/air fl ow
Storage Temperature °C -20 to +85
Humidity (non condensing) - 10 - 95% RH
Cooling - Convection/air fl ow
Withstand Voltage - Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance - >100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 23.52m/s
2
(10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
Shock - < 196.1 m/s
2
(20G)
Safety Agency Certifi cations - UL/CSA/EN60950-1 (2nd Ed) Class I , CE Mark (LVD)
Conducted & Radiated EMI - EN55022-B, FCC Class B
Immunity - EN61000-4-2,-3,-4,-6,-8
Weight (Typ) g 385
Size (WxLxH) in(mm) 3 x 5 x 1.05 in. (76.2 x 127 x 26.6 mm) including underside components
Warranty yrs 2 Years
Specifi cations
(1) 5V measured with 0.1uF ceramic & 220uF electrolytic at 20MHz BW,
all other models measured with 0.1uF & 10uF ceramic electrolytic at 20MHz BW
Key Market Segments & Applications
*Safety certifi ed for 47-63Hz input only