Datasheet
1581-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZPSA100 Series
Features
 PFC
 Wide Range AC Input
 Low Profi le, Industry Standard Footprint
 Global Safety Agency Compliance
 RoHS Compliant
 Up to 84% effi  ciency
 Meets EN61000-4 Immunity
3” x 5” 100W AC-DC Power Supplies
Model    ZPSA100           
Input Voltage range  -  90 - 264VAC (47 - 63Hz) or 120 - 370VDC*
  Inrush Current  A  25 / 50 (cold start)
  Input Current (115/230VAC)  A  1.1 / 0.6
  Temperature Coeffi cient   -  ±0.05%/°C
  Voltage Accuracy  -  ±1%
  Minimum Load  A  None
  Load Regulation  -  ±1%
  Line Regulation  -  ±0.5%
  Ripple & Noise (1)  mV  5V: 2%, others 1%
  Short Circuit Protection  -  Foldback
  Overvoltage Protection  V  Typically 110-130% of nominal, auto recovery
  Hold Up Time (Typ)  ms  16ms at 115VAC input
  Operating Temperature  °C  0 to +70°C with derating/air fl ow
  Storage Temperature  °C  -20 to +85
  Humidity (non condensing)  -  10 - 95% RH
  Cooling  -  Convection/air fl ow
  Withstand Voltage  -  Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
  Isolation Resistance  -  >100M at 25°C & 70%RH, Output to Ground 500VDC
  Vibration (non operating)  -  23.52m/s
2
 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
  Shock  -  < 196.1 m/s
2
 (20G)
  Safety Agency Certifi cations  -  UL/CSA/EN60950-1 (2nd Ed) Class I , CE Mark (LVD)
  Conducted & Radiated EMI  -  EN55022-B, FCC Class B
  Immunity  -  EN61000-4-2,-3,-4,-6,-8
  Weight (Typ)  g  385
  Size (WxLxH)  in(mm)  3 x 5 x 1.05 in. (76.2 x 127 x 26.6 mm) including underside components
  Warranty  yrs  2 Years
Specifi cations
*Safety certifi ed for AC input only.
Notes:
  (1)  5V measured with 0.1uF ceramic & 220uF electrolytic at 20MHz BW,
    all other models measured with 0.1uF & 10uF ceramic electrolytic at 20MHz BW
Key Market Segments & Applications