User manual
 Page 14 of 16               ZPSA100 Series, 17370 issue 5 April 2013 
P
roduct HANDBOOK 
Z
PSA
10
0
 Series
Input Parameters: 
Standard  60950-1 
Rated input voltage  100-240 VAC 
Input voltage range  90 – 264VAC 
Input frequency range  47 – 63Hz 
Maximum input current 
115/240VAC 
130mA/ 
0.70mA 
270mA/ 
0.130mA 
400mA/ 
0.200mA 
Inrush current  30A max at 230VAC 
Class of Equipment  I 
Overvoltage Category  II 
Output Parameters: 
Model  Vout (V)  Output 
current (A) 
5  20 
9  11.2 
12  8.4 
15  6.7 
18  5.6 
24  4.2 
100W 
48  2.1 
Output connector mates with Molex housing 09-50-1081 and Molex 5194 series crimp terminal 
Adjusting output voltage beyond the set value stated may cause overvoltage protection (OVP) to operate, 
whereby the output will latch off. To reset for normal operation simply adjust the potentiometer to reduce the 
output voltage to within its range and cycle the input off then on. 
All outputs are SELV except under the following circumstance: Outputs connected in series are non-SELV if 
the total output voltage exceeds 60Vdc 
If the total voltage of outputs connected in series exceed the 60Vdc SELV limit then all outputs must be 
considered non-SELV. 
Non-SELV outputs are hazardous and must not be made user accessible. Consideration must be given to 
service engineers making inadvertent contact with the output terminals in the end equipment. 
Cooling for unit 
The ZPSA100 series are convection cooled, recommended installation 
Equipment top 