Instructions
120
STATus
:OPERation
[:EVENt]? Returns the value of the Event register SEVE?
:CONDition Returns the value of the Condition register STAT?
:ENABle <NRf> Enables specific bits in the Event register SENA[?]
:QUEStionable
[:EVENt]? Returns the value of the Event register FEVE?
:CONDition Returns the value of the Condition register FLT?
:ENABle <NRf> Enables specific bits in the Event register FENA[?]
SYSTem
:ERRor:ENABle Enable error message <NC>
:ERRor? Read system error messages <NC>
:LANGuage GEN Set communication language LANG[?]
:REMote
[:STATe] LOC|REM|LLO Set the remote/local state RMT[?]
:VERSion? Returns software revision VER?
:DATE? Returns calibration date DATE?
:PON
:TIME? Response time from last reset <NC>
TRIGger
[:STARt] Run trigger <NC>
:DELay <NRf+> Set input trigger delay <NC>
:SOURce EXTernal|BUS Set input trigger source <NC>
<NC> Display Voltage and Current data. Data DVC?
<NC> Reads the complete power supply status. STT?
<NC> Reset the added Fold Back Delay to zero. FBDRST
<NC> Sets the Master/Slave parallel operation mode PMS[?]
<NC> Sets SO signal polarity SOP[?]
<NC> Set factory default parameters FRST
NOTES:
• <NC> - “NO COMMAND” command/query don’t exist.
• [?] – Command and query available (GEN command).
• (*) – command UVP or UVL set protection or limit mode and level