Data Sheet
SWS1000L
DENSEI-LAMBDA R-3
3. Electrical Fast Transient / Burst Immunity Test (IEC61000-4-4)
MODEL : SWS1000L
(1) Equipment Used
EFT/B (Generator) : NSG-2025 (SCHAFFNER)
(2) Test Conditions
Input Voltage : 115, 230VAC Output Voltage : Rated
Output Current : 100% Polarity : + , -
Number of Tests : 3 times Ambient Temperature : 25°C
Test time : 1 minute
(3) Test Method and Device Test Points
Apply to (N,L,FG), (NL), (N), (L), (FG)
Analog Voltmeter
FG
Wooden Table
D.U.T.
Load
Aluminum Plate
GND Plane
FG
0.8 m
EFT/B
Generator
GND
AC INPUT
V
(4) Acceptable Conditions
1. Output voltage regulation not to exceed ±5% of initial (before test) value during test.
2. Output voltage to be within regulation specification after the test.
3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure.
(5) Test Results
Test Voltage (kV) Repetition Rate (kHz) SWS1000L-24
0.5 5.0 PASS
1.0 5.0 PASS
2.0 5.0 PASS