Data Sheet

SWS1000L
DENSEI-LAMBDA R-2
2. Radiated Radio-Frequency Electromagnetic Field Immunity Test
(IEC61000-4-3)
MODEL : SWS1000L
(1) Equipment Used
Test Laboratory : TUV SUD PSB Singapore Accreditation Lab.
(2) Test Conditions
Input Voltage : 115, 230VAC Output Voltage : Rated
Output Current : 100% Amplitude Modulated : 80%, 1kHz
Electromagnetic Frequency : 80~1000MHz Ambient Temperature : 25°C
Distance : 3.0m Wave Angle : Horizontal and Vertical
Sweep Conditions : 1.0% Step Up, 3.0 Seconds Hold
Test Angle : Front, Back, Left, Right, Top, Bottom
(3) Test Method
(4) Acceptable Conditions
1. Output voltage regulation not to exceed ±5% of initial (before test) value during test.
2. Output voltage to be within regulation specification after the test.
3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure.
(5) Test Results
Radiation Field Strength (V/m) SWS1000L-24
1 PASS
3 PASS
10 PASS
Antenna
Anechoic Material to
Reduce Floor Reflections
Wooden Table
FG
AC
INPUT
D.U.T.
Load
Aluminum Plate
GND Plan e
FG
0.8 m
V
_
Analog Voltage Meter