SWS1000L INDEX PAGE 1. Electrostatic Discharge Immunity Test (IEC61000-4-2)……............................................... R-1 2. Radiated Radio-Frequency Electromagnetic Field Immunity Test (IEC61000-4-3)……..... R-2 3. Electrical Fast Transient / Burst Immunity Test (IEC61000-4-4)…………………………… R-3 4. Surge Immunity Test (IEC61000-4-5)……………………………………………………… R-4 5. Conducted Disturbances Induced by Radio-Frequency Field Immunity Test (IEC61000-4-6)......................................................
SWS1000L 1.
SWS1000L 2. Radiated Radio-Frequency Electromagnetic Field Immunity Test (IEC61000-4-3) MODEL : SWS1000L (1) Equipment Used Test Laboratory : TUV SUD PSB Singapore Accreditation Lab. Input Voltage : 115, 230VAC Output Voltage : Rated Output Current : 100% Amplitude Modulated : 80%, 1kHz Electromagnetic Frequency : 80~1000MHz Ambient Temperature : 25°C Distance : 3.0m Wave Angle : Horizontal and Vertical Sweep Conditions : 1.0% Step Up, 3.
SWS1000L 3. Electrical Fast Transient / Burst Immunity Test (IEC61000-4-4) MODEL : SWS1000L (1) Equipment Used EFT/B (Generator) : NSG-2025 (SCHAFFNER) (2) Test Conditions Input Voltage : 115, 230VAC Output Voltage : Rated Output Current : 100% Polarity : +,- Number of Tests : 3 times Ambient Temperature : 25°C Test time : 1 minute (3) Test Method and Device Test Points Apply to (N,L,FG), (NL), (N), (L), (FG) Analog Voltmeter V D.U.T.
SWS1000L 4.
SWS1000L 5. Conducted Disturbances Induced by Radio-Frequency Field Immunity Test (IEC61000-4-6) MODEL : SWS1000L (1) Equipment Used Test Laboratory : TUV SUD PSB Singapore Accreditation Lab. Input Voltage : 115, 230VAC Output Voltage Output Current : 100% Electromagnetic Frequency : Ambient Temperature : 25°C Sweep Conditions : 1.0% Step Up, 3.
SWS1000L 6. Power Frequency Magnetic Field Immunity Test (IEC61000-4-8) MODEL : SWS1000L (1) Equipment Used Test Laboratory : TUV SUD PSB Singapore Accreditation Lab. Input Voltage : 115, 230VAC Output Voltage : Rated Output Current : 100% Magnetic Frequency : 50Hz Test Time : > 10 sec (Each direction) Ambient Temperature : 25oC Direction : X, Y, Z (2) Test Conditions (3) Test Method and Device Test Point Helmholts Coils V AC INPUT Analog Voltage Mater LOAD D.U.T. 1.5m 0.
SWS1000L 7. Voltage Dips, Short Interruptions Immunity Test (IEC61000-4-11) MODEL : SWS1000L (1) Equipment Used Test Generator : Programmable AC Source Model 61505 (CHROMA) Input Voltage : 115, 230VAC Output Voltage : Rated Output Current : 100% Ambient Temperature : 25°C Number of Tests : 3 times Test Interval : > 10 sec. (2) Test Conditions (3) Test Method and Device Test Point Oscilloscope D.U.T. LOAD 0.