Datasheet
SWS1000L 
  DENSEI-LAMBDA R-5 
5. Conducted Disturbances Induced by Radio-Frequency Field 
 Immunity Test (IEC61000-4-6) 
MODEL : SWS1000L 
 (1) Equipment Used 
Test Laboratory    :  TUV SUD PSB Singapore Accreditation Lab. 
 (2) Test Conditions 
Input Voltage  : 115, 230VAC  Output Voltage  : Rated 
Output Current  : 100%  Electromagnetic Frequency : 150kHz~80MHz 
 Ambient Temperature : 25°C  
Sweep Conditions    :  1.0% Step Up, 3.0 Seconds Hold 
(3) Test Method 
(4) Acceptable Conditions 
1.   Output voltage regulation not to exceed ±5% of initial (before test) value during test. 
2.   Output voltage to be within regulation specification after the test. 
3.   Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 
(5) Test Results 
Test Voltage (V)  SWS1000L-24 
1 PASS 
3 PASS 
10 PASS 
Aluminium Plate
Wooden Table
LOAD
D.U.T
GND
FG
V
CDN
AC INPUT
RF INPUT
FG
Analog Voltage Meter
10cm
GND Plane
10 ~ 30 cm