6.  Power Frequency Magnetic Field Immunity Test (IEC61000-4-8) 
MODEL :  SWS1000L 
(1) Equipment Used 
Test Laboratory  :  TUV SUD PSB Singapore Accreditation Lab. 
(2) Test Conditions 
 Input Voltage  : 115, 230VAC  Output Voltage  : Rated 
 Output Current : 100%  Magnetic Frequency  : 50Hz 
  Test Time    :  > 10 sec (Each direction)  Ambient Temperature  :  25
o
C 
  Direction    :  X, Y, Z 
(3) Test Method and Device Test Point 
(4) Acceptable Conditions 
1.  Output voltage regulation not to exceed +
5% of initial (before test) value during test. 
2.  Output voltage to be within output voltage regulation specification after the test. 
3.  Along with 1 and 2, no discharge of fire or smoke, as well as no output failure.  
(5) Test Result 
Magnetic Field Strength (A/m)  SWS1000L-24 
1 PASS 
3 PASS 
10 PASS 
30 PASS 
Helmholts Coils 
1.5m 
AC INPUT 
LOAD 
D.U.T. 
Wooden Table 
0.8m
Analog Voltage Mater 
V
AC Power 
Source 
Shunt 
Resistor
Signal Phase 
Analyzer 