Datasheet
SWS1000L 
  DENSEI-LAMBDA R-2 
2.  Radiated Radio-Frequency Electromagnetic Field Immunity Test 
(IEC61000-4-3) 
MODEL :  SWS1000L 
 (1) Equipment Used 
Test Laboratory    : TUV SUD PSB Singapore Accreditation Lab. 
(2) Test Conditions 
Input Voltage     : 115, 230VAC    Output Voltage    : Rated 
Output Current    : 100%      Amplitude Modulated  : 80%, 1kHz 
  Electromagnetic Frequency : 80~1000MHz    Ambient Temperature  : 25°C 
 Distance  :     3.0m  Wave Angle  : Horizontal and Vertical 
  Sweep Conditions    : 1.0% Step Up, 3.0 Seconds Hold 
  Test Angle      : Front, Back, Left, Right, Top, Bottom 
(3) Test Method 
(4) Acceptable Conditions 
1.   Output voltage regulation not to exceed ±5% of initial (before test) value during test. 
2.   Output voltage to be within regulation specification after the test. 
3.   Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 
(5) Test Results 
Radiation Field Strength (V/m)  SWS1000L-24 
1 PASS 
3 PASS 
10 PASS 
Antenna
Anechoic Material to 
Reduce Floor Reflections
Wooden Table
FG
AC
INPUT
D.U.T.
Load
Aluminum Plate
GND Plan e
FG
0.8 m
V
_
Analog Voltage Meter