Datasheet
SWS1000L 
  DENSEI-LAMBDA  R-1 
1.  Electrostatic Discharge Immunity Test (IEC61000-4-2) 
MODEL :  SWS1000L 
 (1) Equipment Used 
Electrostatic Discharge Simulator  :  NSG435    (SCHAFFNER) 
Discharge Resistance    :  330Ω  Capacitor : 150pF 
 (2) Test Conditions 
Input Voltage  : 115, 230VAC  Output Voltage  : Rated 
Output Current : 100%  Polarity  : +, - 
  Number of Tests  :  10 times        Ambient Temperature  :  25°C 
  Discharge Interval  :  >1 Second         
(3) Test Method and Device Test Point 
Contact Discharge  :  FG, Case Screw 
Air Discharge  :  Input and Output Terminal, FG, Case Screw 
FG
Wooden Table
 OUTPUT
GND
Electrostatic
Discharge Simulator
AC
INPUT
D.U.T.
Load
Aluminum Plate
GND Plane
Discharge Probe
FG
0.8 m
Analog Voltmeter
V
(4) Acceptable Conditions 
1.   Output voltage regulation not to exceed ±5% of initial (before test) value during test. 
2.   Output voltage to be within regulation specification after the test. 
3.   Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 
(5) Test Results 
Contact Discharge 
(kV) 
SWS1000L-24 
Air Discharge 
(kV) 
SWS1000L-24 
2 PASS 2 PASS 
4 PASS 4 PASS 
6 PASS 8 PASS 