Datasheet
SWS1000L 
   DENSEI-LAMBDA   R-2 
2. 
Component derating 
 MODEL : SWS1000L-5 
(1) Calculating method 
 (a) Measuring Conditions 
 Input  : 115 , 230VAC  Ambient temperature  : 50°C 
 Output  : 5V 200A (100%)   Mounting method  : Mounting A 
 (b) Semiconductors 
Compared with maximum junction temperature and actual one which is calculated 
based on case temperature, power dissipation and thermal impedance. 
 (c) IC, Resistors, Capacitors, etc. 
Ambient temperature, operating condition, power dissipation and so on are within 
derating criteria. 
 (d) Calculating Method of Thermal Impedance 
θ
 =
T-T
P
j-c
j(max) c
c(max)
θ
 j-a
j(max) a
c(max)
=
T-T
P
θ
 j-l
j(max) l
c(max)
=
T-T
P
   : Case temperature at start point of derating ; 25°C in general 
   : Ambient temperature at start point of derating ; 25°C in general 
   : Lead temperature at start point of derating ; 25°C in general 
(
P
ch(max)
)
(
T
ch(max)
)
(
θ
ch - c
) 
   : Thermal impedance between junction and air 
   : Thermal impedance between junction and lead 
: Maximum collector(channel) dissipation 
: Maximum junction(channel) temperature 
: Thermal impedance between junction(channel) and case 
T
c
T
a
T
l
P
c(max)
T
j(max)
θ
j-c
θ
j-a
θ
j-l