Datasheet

SWS1000L
DENSEI-LAMBDA R-20
8. Thermal shock test
MODEL : SWS1000L-5
(1) Equipment used
THERMAL SHOCK CHAMBER TSV-40 (TABAI ESPEC CORP.)
(2) The number of D.U.T.(Device Under Test)
1 unit
(3) Test Conditions
Ambient temperature : -40°C ~ 85°C
Test time : Refer to drawing
Test cycle : 100 cycles
Not operating
(4) Test Method
Before testing, check if there is no abnormal output, then put the D.U.T. in testing chamber,
and test it according to the above cycle. 100 cycles later, leave it for 1 hour at the room temperature,
then check if there is no abnormal output.
(5) Test Results
O K
-40°C
1Cycle
85°C
30min
30min