Datasheet
SWS1000L
2. CHARACTERISTICS
2.1 Steady State Data
(1) Regulation - Line and Load, Temperature Drift
5V
1.1 Regulation - Line and Load
Conditions:
Ta = 25°C
85Vac 115Vac 230Vac 265Vac
4.989V 4.989V 4.990V 4.990V 0.001V 0.02%
4.986V 4.987V 4.989V 4.990V 0.004V 0.08%
4.984V 4.987V 4.986V 4.987V 0.003V 0.06%
0.005V 0.002V 0.004V 0.003V
0.10% 0.04% 0.08% 0.06%
.
1.2 Temperature Drift
Conditions:
Vin = 115Vac
Iout =
100%
-20°C 25°C 50°C
4.977V 4.987V 4.982V 0.010V 0.20%
12V
1.1 Regulation - Line and Load
Conditions:
Ta = 25°C
85Vac 115Vac 230Vac 265Vac
12.097V 12.097V 12.097V 12.097V 0.000V 0.00%
12.097V 12.097V 12.086V 12.097V 0.011V 0.09%
12.092V 12.092V 12.097V 12.097V 0.005V 0.04%
0.005V 0.005V 0.011V 0.000V
0.04% 0.04% 0.09% 0.00%
.
1.2 Temperature Drift
Conditions:
Vin = 115Vac
Iout =
100%
-20°C 25°C 50°C
12.043V 12.092V 12.103V 0.060V 0.50%
24V
1.1 Regulation - Line and Load
Conditions:
Ta = 25°C
85Vac 115Vac 230Vac 265Vac
24.204V 24.193V 24.188V 24.188V 0.016V 0.07%
24.204V 24.193V 24.177V 24.177V 0.027V 0.11%
24.198V 24.182V 24.182V 24.188V 0.016V 0.07%
0.006V 0.011V 0.011V 0.011V
0.03% 0.05% 0.05% 0.05%
.
1.2 Temperature Drift
Conditions:
Vin = 115Vac
Iout =
100%
-20°C 25°C 50°C
23.991V 24.182V 24.226V 0.235V 0.98%
Line Regulation
Vout
Temp. StabilityTa
Load
Regulation
0%
50%
100%
Io \ Vin
Io \ Vin Line Regulation
0%
50%
Line Regulation
0%
100%
Load
Regulation
Ta Temp. Stability
Ta Temp. Stability
Vout
50%
100%
Load
Regulation
Vout
Io \ Vin
DENSEI-LAMBDA
T-7