Datasheet
201-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
RWS-B Series
Features
 Low Cost   
 Wide Range AC Input 85 - 265VAC (300VAC for 5s)   
 UL508 Certifi cation on Select Models   
 Enclosed Construction   
 Compact Size   
 7 Year Warranty
50-600W Single Output General Purpose Power Supplies
  Model      RWS50B  RWS100B  RWS150B  RWS300B  RWS600B
AC Input Voltage range (1)    VAC  85 - 265VAC (47 - 63Hz), 300VAC for 5 seconds   
  DC Input Voltage range    VDC  120 - 370VDC (330VDC for RWS600B)*     
  Inrush Current (100 / 200VAC)   A  18 / 36  15 / 30  16 / 32  17 / 34  20 / 40
  Power Factor (100 / 200VAC)    -  Meets EN61000-3-2 (0.95 / 0.9)     
          1.2 / 0.6  1.8 / 0.9  3.6 / 1.9  6.6 / 3.6
  Input Current (115/230VAC) (Typ)  A  1.0 / 0.65  (5V: 0.9/0.45)  (5V: 1.3/0.7)  (5V: 3.1/1.6)  (5V: 6.2/3.2)
  Temperature Coeffi cient    -  <0.02%/°C     
  Regulation    -  See sheet 2     
  Overcurrent Protection    -  >105%, Constant Current Style     
  Overvoltage Protection    V  115-140%, Cycle AC line to reset     
  Hold Up Time (Typ at 100% load)  ms  20ms (RWS50B: 15ms at 100VAC input)     
  Leakage Current (max)    uA  750uA maximum, typically 175uA at 115VAC, 63Hz   
  Remote Sense    -  No    
  Operating Temperature    -  -20 to +70
o
C, see note (3) and instruction manual for low temperature derating
  Storage Temperature    -  -30 to +75°C     
  Operating Humidity (non condensing)  %RH  30 - 90%RH     
  Storage Humidity (non condensing)  %RH  10 - 90%RH     
  Cooling    -  Convection  Internal Fan 
  Withstand Voltage    -  Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
  Isolation Resistance    -  >100M at 25°C & 70%RH, Output to Ground 500VDC   
  Vibration (non operating)    -  10 - 55Hz: 19.6m/s
2
 (sweep 1 min) X, Y, Z for 1 hour   
  Shock    -  < 196.1 m/s
2
  Safety Agency Approvals (2)  -  UL / CSA(cUL) / IEC 60950-1 (2nd Ed), UL:508, CSA C22.2 No.107.1-01,
        CE Mark (Additionally evaluated to EN 60950-1)
  Conducted & Radiated EMI  -  EN55011 / EN55022-B, FCC Class B, VCCI-B   
  Line Dips    -  SEMI-F47 (200VAC input)
  Immunity    -  IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2   
  Weight (Typ)    g  230  400  480  900  1600
  Size (WxHxD)    mm  82 x 34 x 81.5  94 x 39 x 108  94 x 41 x 128  102 x 41 x 170  120 x 61 x 190
      In  3.23 x 1.34 x 3.2  3.7 x 1.54 x 4.25  3.7 x 1.61 x 5.04  4.02 x 1.61 x 6.7  4.72 x 2.4 x 7.48
  MTBF - Telcordia SR-332 issue 3**  Hours  4,170,949  1,978,533  2,235,743  2,027,824  2,157,340
  Warranty    Yrs  Seven Years 
Specifi cations
Notes:  (1) See instruction manual for derating below 115VAC input           
    (2) UL508 & CSA C22.2 No.107.1-01 on RWS50B-5, -12, -24, RWS100B-5, -12, -24, RWS150B-5, -12, -24, RWS300B-12, -15, -24, -36 & -48 RWS600B-24 only   
    (3) RWS50-100B derates linearly above 45
o
C to 20% load at 70
o
C, 150B derates above 40
o
C and 300-600B derates above 50
o
C to 50% load at 70
o
C
*Safety certifi ed for AC input only ** 24V output model, 25°C ambiient, full load, 230VAC input
Key Market Segments & Applications