Input Specification
Parameter Model Min Typ Max Unit
Operating Input Voltage 24Sxx
48Sxx
18
36
24
48
36
75
Vdc
InputCurrent
(Maximum Valueat Vin= Vin(nom); Full Load)
24S3P3
24S05
24S12
24S15
48S3P3
48S05
48S12
48S15
2264
2941
2907
2907
1132
1453
1453
1453
mA
InputStandby Current
(Typical Value atVin = Vin(nom); No Load)
24S3P3
24S05
24S12
24S15
48S3P3
48S05
48S12
48S15
100
130
150
150
80
90
100
100
mA
Under Voltage Lockout Turn-on Threshold 24Sxx
48Sxx
17
34
Vdc
Under Voltage Lockout Turn-offThreshold 24Sxx
48Sxx
15
32
Vdc
InputReflected Ripple Current
(5 to 20MHz, 12μH Source Impedance)
All 20 mAp-p
Start UpTime
(Vin = Vin(nom) and Constant Resistive Load)
Power Up
Remote ON/OFF
All
20
20
ms
Remote ON/OFF Control
(The ON/OFFpin voltage is referencedto -V
IN
)
Negative Logic DC-DC ON(Short)
DC-DC OFF(Open)
Positive Logic DC-DC ON(Open)
DC-DC OFF(Short)
All
0
3
3
0
1.2
12
12
1.2
Vdc
Remote Off Input Current ALL 4 mA
InputCurrent of Remote Control Pin