Datasheet

DataSheet
60W, Single Output
VER:00 Page 22 of 31 Issued Date2009/03/02
EMC considerations
Suggested Schematic for EN55022 Conducted Emission ClassALimits
Recommended Layout with Input Filter
To meet conducted emissions EN55022 CLASSAneeded the following components:
PXF60-24Sxx
Component Value Voltage Reference
C2 6.8uF 50V 1812 MLCC
C3,C4 1000pF 2KV 1808MLCC
PXF60-48Sxx
Component Value Voltage Reference
C1,C2 2.2uF 100V 1812 MLCC
C3,C4 1000pF 2KV 1808 MLCC