Datasheet
DataSheet
40W, Single Output
VER:00 Page 29 of 31 Issued Date:2009/03/02
Remote Sense Application Circuit
The Remote Sense function, when used, regulates the voltage at the load terminals; this
compensates for any voltage drop that mayexist between the output of the converter and the load. The
voltage compensation is limited to less than 10 % of the nominal output voltage rating of the converter.
i.e.:
[Vo (+) to Vo (-)] – [Sense (+) to Sense (-)] < 10% Vo
If the Remote Sense function is not used the SENSE (+) should be connected to OUTPUT
(+) and
the SENSE (-) should be connected to OUTPUT(-) of the converter.
Remote Sense shown connected to the load.
Soldering Consideration
Lead free wave solder profile for PXF40WS-SERIES
Zone Reference Parameter
Preheat zone Rise temp.speed : 3°C/ sec max.
Preheat temp. : 100~130°C
Actual heating Peak temp. : 250~260°C
Peak time (T1+T2 time) : 4~6 sec
Reference Solder:Sn-Ag-Cu / Sn-Cu
Hand Welding:Soldering iron- Power90W
Welding Time: 2-4 sec
Temp.:380-400 °C