Datasheet

DataSheet
40W, Triple Output
VER:00 Page 2 of 40 Issued Date2009/03/02
Absolute Maximum Rating
Parameter Model Min Max Unit
InputVoltage
Continuous
Transient(100ms)
12Txxxx
24Txxxx
48Txxxx
12Txxxx
24Txxxx
48Txxxx
18
36
75
36
50
100
Vdc
OperatingAmbient Temperature (with derating) All -40 85
°C
Operating CaseTemperature All 100
°C
StorageTemperature All -55 105
°C
Output Specification
Parameter Model Min Typ Max Unit
OutputVoltage
(Vin = Vin(nom) ; FullLoad ; T
A
=25°C)
xxT3312
xxT3315
xxT0512
xxT0515
3.267/±11.4
3.267/±14.25
4.95/±11.4
4.95/±14.25
3.3 /±12
3.3 /±15
5 /±12
5 /±15
3.333/±12.6
3.333/±15.75
5.05/±12.6
5.05/±15.75
Vdc
OutputRegulation
Line(Vin(min) to Vin(max) atFull Load)
Load (Min.to 100%of FullLoad)
Main
Auxiliary
Main
Auxiliary
-1
-5
-2
-5
+1
+5
+2
+5
%
OutputRipple& Noise (See Page29 )
Peak-to-Peak (20MHz bandwidth)
(Measured with a 0.1μF/50V MLCC)
All 50 / 75 mVp-p
Temperature Coefficient All -0.02 +0.02 %/
OutputVoltage Overshoot
(Vin(min) toVin(max) ; Full Load ; T
A
=25°C )
All 0 5 % Vo
DynamicLoad Response
(Vin = Vin(nom) ; T
A
=25°C)
Loadstep changefrom75% to 100% or
100 to 75% of Full Load
Peak Deviation
SettlingTime (V
OUT
10%peak deviation)
All
All
250
250
mV
μS
OutputCurrent xxT3312
xxT3315
xxT0512
xxT0515
600 ± 40
600 ± 30
600 ± 40
600 ± 30
6000 / ±400
6000 / ±300
6000 / ±400
6000 / ±300
mA
OutputOver Voltage Protection
(Zenerdiodeclamp)
xxT3312
xxT3315
xxT0512
xxT0515
3.9/15
3.9/18
6.2/15
6.2/18
Vdc
OutputOver Current Protection All 150 % FL.
OutputShort CircuitProtection All Hiccup,automatic recovery