30W, Single Output
VER:00 Page 61 of 61 Issued Date:2009/03/02
Safety and Installation Instruction
Fusing Consideration
Caution:This converter is not internallyfused.An input line fuse must always be used.
This encapsulated converter can be used in a wide variety of applications, ranging from simple stand-
alone
operation to an integrated part of a sophisticated power architecture. For
maximum flexibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety
agencies require a slow-blow fuse with maximum ratingof 6A. Based on the i
nformation provided in this data sheet on
Inrush energy and maximum DC
input current; the same type of fuse with lower rating can be used. Refer to the fuse
manufacturer’s data for further information.
MTBF and Reliability
The MTBF of PXE30-xxSxx DC/DC converters hasbeencalculated using:
Bellcore TR-NWT-000332 Case I: 50% stress, Operating Temperature at 40°C (Ground fixed and controlled
environment). The resulting figure for MTBF is 1.316×10
6
hours.
MIL-HDBK-217F NOTICE2 FULL LOAD, Operating Temperature at 25°C ℃. The resulting figure for MTBF is
3.465×10
5
hours.