Datasheet

DataSheet
30W, Single Output
VER:00 Page 46 of 46 Issued Date:2009/03/02
Safety and Installation Instruction
Fusing Consideration
Caution: This converterisnotinternally fused.An input line fuse must always be used.
This encapsulated converter can be used in a wide variety of applications, ranging from simple stand-
alone
operation to an integrated part of sophisticated power architecture. For
maximum flexibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety
agencies require a slow-blow fuse with maximum rating of 6A. Based on the information provided in this
data sheet on
inrush energy and maximum DC
input current; the same type of fuse with lower rating can be used. Refer to the fuse
manufacturer’s data for further information.
MTBF and Reliability
The MTBF of PXE30-xxWSxx DC/DC converter hasbeen calculated using
Bellcore TR-NWT-000332 Case I: 50% stress, Operating Temperature at 40°C (Ground fixed and controlled
environment ). The resulting figure for MTBFis 1.315×10
6
hours.
MIL-HDBK-217F NOTICE2 FULL LOAD, Operating Temperature at 25°C ℃. The resulting figure for MTBF is
3.456×10
5
hours.