Datasheet
1641-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
PXE Series
Features
 Industry Standard 2” x 1.6” Footprint
 Six Sided Shielding
 Agency Approved
 12V, 24V and 48V Inputs
 UL, CSA, EN, CE approvals
 Wide range input
20-30W Single and Dual Output DC-DC Converters
Notes:
  (1) To meet regulation & noise specifi cations. Operation at zero load will not damage the device
  (2) 12uH source impedance in series with + input
  (3) Max sink current 20mA (PXE20), 2.5mA (PXE30); The on/off pin is referenced to the negative input
Model  PXE20  PXE30
Max Output Power      20W    30W
 Voltage Accuracy      ±2%    ±1%
 Voltage Adjustment      ±10%
  Minimum Load, each output  (1)    10%    10%
  Line Regulation      ±0.2% for single, ±0.5% for dual 
  Load Regulation (25% to 100%)      Single ±0.5%, Dual ±3%    Single ±0.5%, Dual ±1%
  Cross Regulation (25% to 100%)      Dual ±5%
  Ripple and Noise (P-P)      Single: 75mV; Dual: 100mV
  Start up time      20ms - 1100ms typ.    10 - 25ms typ.
  Remote on/off  (3)    Positive Logic: ON: Open or 3.5-12V, OFF Short or <1.2V
 Temperature Coeffi cient      <±0.02%/°C
  Operating Temperature      -40 to +100°C, see derating curve
  Maximum Case Temperature      100°C (Over temperature protection at 115°C - PXE30 model)
  Storage Temperature      -55 to 105°C
 Thermal Shock      MIL-STD-810D
  Relative Humidity (non condensing)    5 to 95%
  Transient Response (25% step load change)  500us recovery    300us recovery
  Overvoltage Protection (Zener clamp    3.3V: 3.9V, 5V: 6.2V, 12V: 15V, 15V: 18V
  Overcurrent and Short Circuit Protection    Typically at 150%, hiccup with self recovery
  Input Surge Voltage (Maximum for 100ms)  12V input: 36V, 24V input: 50V, 48V input: 100V
 Refl ected input ripple (peak to peak) (2)    25mA 30mA
  Isolation Voltage      1600VDC minimum (Input-Output, Input-Case)
 Isolation Resistance      10
9
 Ohms minimum
  Isolation Capacitance (max)      300pF    1000pF
  Typical Switching Frequency (Fixed)    300kHz
  MTBF (BELLCORE TR-NWT-000332)    1,976,000 hours    1,535,000 hours
  Vibration      10 - 55Hz, 2G, 30 minutes each X, Y, Z axis
  Conducted and Radiated Emissions      See Installation Diagrams
  Immunity      EN61000-4-2, -3, -4, -5, -6 Pref Criteria 2
  Safety Agency Approval      IEC60950-1, UL60950-1, EN60950-1, CE Mark (48V input only)
  Size (L x W x H)      2 x 1.6 x 0.4”
  Weight      1.69 oz (48g)
 Warranty      Two Year
Specifi cations
Key Market Segments & Applications