Datasheet

DataSheet
30W, Single Output
VER:01 Page 3 of 44 Issued Date2009/06/22
Output Specification(Continued)
Parameter Model Min Typ Max Unit
Output OverVoltage Protection
(Zener diode clamp)
xxWS1P5
xxWS2P5
xxWS3P3
xxWS05
xxWS5P1
xxWS12
xxWS15
2.0
3.3
3.9
6.2
6.2
15
18
Vdc
Output OverCurrent Protection All 150 % FL.
Output Short Circuit Protection All Hiccup, automatic recovery
Input Specification
Parameter Model Min Typ Max Unit
Operating Input Voltage 24WSxx
48WSxx
9
18
24
48
36
75
Vdc
InputCurrent
(Maximum value at Vin = Vin(nom); FullLoad)
24WS1P5
24WS2P5
24WS3P3
24WS05
24WS5P1
24WS12
24WS15
48WS1P5
48WS2P5
48WS3P3
48WS05
48WS5P1
48WS12
48WS15
700
1054
1258
1488
1517
1471
1471
350
520
629
744
759
727
718
mA
InputStandby current
(Typical value at Vin = Vin(nom); No Load)
24WS1P5
24WS2P5
24WS3P3
24WS05
24WS5P1
24WS12
24WS15
48WS1P5
48WS2P5
48WS3P3
48WS05
48WS5P1
48WS12
48WS15
70
70
70
105
105
20
30
30
45
45
65
65
60
50
mA
Under Voltage Lockout Turn-on Threshold 24WSxx
48WSxx
9
36
Vdc
Under Voltage Lockout Turn-offThreshold 24WSxx
48WSxx
8
32
Vdc