Thermal Consideration
The power module operates in a variety of thermal environments. However, s
ufficient cooling should be provided to help ensure
reliable operation of the unit. Heat is removed by conduction, convection, and radiation to the surrounding e
nvironment. Proper cooling
can be verifiedbymeasuring the point as indicated in the figure below. Thetemperature at this location should not exceed 100°C
.When
operating, adequate cooling must be provided to maintain the test point temperature at or below 100°C. Although the maximum
temperatureof the powermodule is100°C,decreasingthis temperaturewill yield higher reliability.
Measurementshown ininches(mm) TOPVIEW
Following arederating curves for models: PXD20-24S1P8, 48S05 and 48S15.
PXD20-24S1P8 Derating Curve
0.0
20.0
40.0
60.0
80.0
100.0
120.0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature( °C)
Output Power(%)
Nature convection
Nature convection
With heat
-
sink