Datasheet

131-800-526-2324 • www.us.tdk-lambda.com/lp/
PAH Series
Features
u Industry Standard Footprint & Pinouts
u 12V output for driving non-isolated converters
u Safety Approved
u Full power at 100ºC baseplate
u Wide Adjustable Output Range
u Zero Pre-load
u ASIC Design
u No potting materials
50W to 200W 48V Input Half brick DC-DC Converters
(1) See options table.
General: See Installation Manual for full details, test methods of parameters and application notes
  Model        2.5V  3.3V  5V  12V  15V  24V  28V  48V 
  Effi ciency (Typ)      %  75-76  79-80  83-84  85-86     86-88    88
  Input Voltage range     VDC  36-76
  Output Voltage Accuracy      %  ±1.6
  Max Ripple & Noise      mV  150  200  280  250
  Max Line Regulation     mV    10    24  30  48  56  96
  Max Load Regulation     mV    10    24  30  48  56  96
  Overcurrent Protection      A  105 - 150% automatic recovery
  Overvoltage Protection  (1)    %  120-160  120-140      125-145      135-155
  Remote Sense      -  Yes
  Remote On/Off      -  Standard; Low = ON, Open = OFF /P option; Low = OFF, Open = ON)
  Operating Temperature      -  -40ºC to +100ºC baseplate
  Overtemperature      -  Shutdown between 105 - 130ºC, Auto restart
  Cooling      -  Conduction (See Installation Manual for heatsink selection)
  Isolation Voltage      V  Input - Baseplate 1500VAC, Input - Output 1500VAC, Output-Baseplate 500VDC
  Shock      -  196.1m/s
2
  Vibration      -  Non Operating, 10-55Hz (sweep for 1 min.)
 Amplitude      -  0.825mm constant (Max 49 m/s
2
) X,Y,Z 1 hour each
  Safety Agency Approvals      -  UL60950-1, CSA60950-1, EN60950-1, CE LVD
  Weight (Typ)      g  80
  Size (WxHxD)     in(mm)  2.28x0.5x2.4 (57.9x12.7x61) See outline drawing
  Warranty      -  2 Years
Specifi cations
Key Market Segments & Applications