Datasheet

131-800-526-2324 • www.us.tdk-lambda.com/lp/
PAF600F Series
Features
u 12V output for driving non-isolated converters
u Safety Approved
u Full power at 100°C baseplate
u Opto Isolated Remote On / Off
u Wide Adjustable Output Range
u Parallel Pin
u ASIC Design
u 24V & 48V Inputs
24V & 48V Input Full brick DC-DC Converters
Note: See Installation Manual for full details, test methods of parameters and application notes.
PAF600F24-12 PAF600F24-28
Model PAF600F48-12 PAF600F48-28
Nominal Output Voltage VDC 12 28
Output Current (Max) A 50 21.5
Output Power (Max) W 600 602
Effi ciency (Typ) % 89 to 90%
Input Voltage Range VDC 20-36 / 36-76 19-36 / 36-76
Input Current (Typ) 24/48V input A 28.9 / 14.2 28.9 / 14.1
Output Voltage Accuracy % ±1
Output Voltage Adjustment VDC 7.2 - 13.2 16.8 - 30.8
Ripple & Noise (Max) mV 200 280
Line Regulation (Max) mV 24 56
Load Regulation (Max) mV 24 56
Temperature Coeffi cient - 0.02%/°C
Overcurrent Protection % 105 - 140%
Overvoltage Protection % 115-135%
Signals & Control - Remote sense, remote On/Off, Parallel Pin, DC Good, 7-10V Auxiliary voltage
Operating Temperature - -40°C to +100°C baseplate
Humidity (operating) - 30-95% RH Non condensing
Humidity (storage) - 10-95% RH Non condensing
Cooling - Conduction (See Installation Manual for heatsink selection)
Isolation Voltage VDC Input - Baseplate 1500V, Input - Output 1500V, Output-Baseplate 500V (for 1 min.)
Shock - 196.1m/s
2
Vibration - Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s
2
) X,Y,Z 1 hour each
Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1, CE LVD (48V model only)
Weight (Typ) g 250
Size (WxHxD in(mm) 2.4 x 0.5 x 4.6 (61 x 12.7 x 116.8) See outline drawing
Warranty - 2 years
Specifi cations
Key Market Segments & Applications

Summary of content (2 pages)