Instructions
Table Of Contents
- LS50(75(100(150 Series
- Instruction Manual
- 1. Terminal Explanation
- LS50, LS75
- 2. Terminal connecting method
- LS50, LS75 LS100, LS150
- Maximum output current of each output terminal is 25A. If more than 25A, use 2 terminals
- 3. Explanation of Functions and Precautions
- 3-1. Input Voltage Range
- 3-2. Output Voltage Range
- 3-3. Inrush Current
- 3-4. Over Voltage Protection (OVP)
- 3-5. Over Current Protection (OCP)
- 3-6. Output Ripple & Noise
- 3-7. Series Operation
- 3-8. Parallel Operation
- 4. Isolation / Withstand Voltage
- 4-1. Isolation Test
- 4-2. Withstand Voltage
- 5-1. Output Derating according to the Mounting Directions
- NOTE : LS50, LS75 & LS150 series do not require Input Voltage Derating.
- 5-2 Mounting Method
- Note 1 : When using separate loads, use of two pcs of 0.8mm thick crimp-type terminal is recommended.
- 7. External Fuse Rating
- 8. Before concluding that the unit is at fault…

NEMIC-LAMBDA
LS50
⋅
75
⋅
100
⋅
150 Series
INSTRUCTION MANUAL
(B) Output Derating versus Input Voltage (Convection Cooling)
LS100-3.3, -5, -12, -15, -24, -36 & -48
Output Derating Vs Input Voltage
0
20
40
60
80
100
120
88 230
Vin (VAC)
LOAD (%)
115
264
NOTE : LS50, LS75 & LS150 series do not require Input Voltage Derating.
5-2 Mounting Method
1) This is convection cooling type power supply. In consideration of the heat radiation and safety, please keep a dis-
tance of more than 15mm between the power supply and the peripheral parts. When lining up multiple units, please
make sure to place them 15mm or more apart from each other.
2) The maximum allowable penetration of mounting screws is 5mm.
3) Recommended torque for mounting screw LS50, LS75, LS100 & LS150 (M3 screw) : 0.49 N⋅m (5.0 kgf⋅cm).