Datasheet

KWS-A Series
3
Notes:
See website for detailed specications, test methods and installation manual
*24V model, 25°C ambient, full load, 230Vac Input
(1) Safety certied for AC input 47-63Hz only
(2) At 100Vac and 115Vac with 80% load (70% load for KWSA10), 200Vac and 230Vac with 100% load
(3) KWS10A-5, KWS15A-5, KWS25A-5: Derate linearly to 10% load from +45 to +85°C
Specications
Model KWS5A KWS10A KWS15A KWS25A
Environmental
Operating Temperature °C -40 start-up; -10 to +85. Derate linearly to 10% load from +55 to +85
(3)
Storage Temperature °C -40 to +85
Humidity (non condensing) %RH 30 - 90 Operating, 20 - 95 Storage
Cooling - Convection
Altitude m 3000
Withstand Voltage (For 1 minute) Vac Input to Output 3,000
Isolation Resistance >100 at 25°C, 70%RH & 500VDC
Vibration (non operating) - 10-55Hz (Sweep for 1min.) Amplitude 1.65 mm (Max 10G, 98m/s
2
) Constant X,Y,Z 1 hour each
Shock (non operating) - Less than 50G (490m/s
2
), 11ms, ±X, ±Y, ±Z 3 times each
Other
Weight (Typ) g 35 35 60 85
Size (LxWxH) mm 38.1 x 25.4 x 21.5 38.1 x 25.4 x 21.5 50.8 x 25.4 x 24 63.5 x 25.4 x 29
Size (LxWxH) Inches 1.5 x 1.0 x 0.85 1.5 x 1.0 x 0.85 2.0 x 1.0 x 0.94 2.5 x 1.0 x 1.14
Case Material - Plastic, UL94V0
MTBF - Telcordia SR-332 issue 3* Hours 14,416,059 7,784,121 8,202,502 5,747,627
Warranty yrs 3
KWS5A, KWS10A Outline Drawing