Datasheet
Data Sheet: Asceta
TM
 iQG Series –Single Output Quarter Brick 
© 2001 - 2012 TDK Innoveta Inc. 
iQG 12V/33A Droop Load Share Rev 1.4 2/15/2012 
(
877
)
 498-0099
14/15 
EMC Considerations:  TDK Innoveta power 
modules are designed for use in a wide 
variety of systems and applications. With 
the help of external EMI filters and careful 
layout, it is possible to meet CISPR 22 class 
A or B requirement. For assistance with 
designing for EMC compliance, please 
contact TDK Innoveta technical support. 
Input Impedance: The source impedance 
of the power feeding the DC/DC converter 
module will interact with the DC/DC 
converter. To minimize the interaction, one 
or more 220uF to 470uF/100V input 
electrolytic capacitors should be present if 
the source inductance is greater than 4uH. 
Reliability:
The power modules are designed using TDK 
Innoveta’s stringent design guidelines for 
component derating, product qualification, 
and design reviews. Early failures are 
screened out by both burn-in and an 
automated final test. The MTBF is 
calculated to be 2.9M hours at nominal 
input, full load, and Ta = 40˚C using the 
Telcordia TR-332 issue 6 method. 
Improper handling or cleaning processes 
can adversely affect the appearance, 
testability, and reliability of the power 
modules. Contact TDK Innoveta technical 
support for guidance regarding proper 
handling, cleaning, and soldering of TDK 
Innoveta’s power modules. 
Quality:
TDK Innoveta’s product development 
process incorporates advanced quality 
planning tools such as FMEA and Cpk 
analysis to ensure designs are robust and 
reliable. All products are assembled at ISO 
certified assembly plants. 
Safety Considerations:
For safety agency approval of the system in 
which the DC-DC power module is installed,  
the power module must be installed in 
compliance with the creepage and clearance 
requirements of the safety agency. The 
isolation is basic insulation. For 
applications requiring basic insulation, care 
must be taken to maintain minimum 
creepage and clearance distances when 
routing traces near the power module. 
As part of the production process, the power 
modules are hi-pot tested from primary and 
secondary at a test voltage of 1500Vdc. 
To preserve maximum flexibility, the power 
modules are NOT internally fused. An 
external input line normal blow fuse with a 
maximum value of 15A is required by safety 
agencies. A lower value fuse can be 
selected based upon the maximum dc input 
current and inrush energy of the module. 
When the supply to the DC-DC converter is 
less than 60Vdc, the power module meets 
all of the requirements for SELV. If the 
input voltage is a hazardous voltage that 
exceeds 60Vdc, the output can be 
considered SELV only if the following 
conditions are met: 
1)  The input source is isolated from the 
ac mains by reinforced insulation. 
2)  The input terminal pins are not 
accessible. 
3)  One pole of the input and one pole of 
the output are grounded or both are 
kept floating. 
4)  Single fault testing is performed on the 
end system to ensure that under a 
single fault, hazardous voltages do not 
appear at the module output. 
Warranty:
TDK Innoveta’s comprehensive line of 
power solutions includes efficient, high-
density DC-DC converters. TDK Innoveta 
offers a three-year limited warranty. 
Complete warranty information is listed on 
our web site or is available upon request 
from TDK Innoveta.