Operating Information: 
Over-Current Protection: The power 
modules have current limit protection to 
protect the module during output overload 
and short circuit conditions. During overload 
conditions, the power modules may protect 
themselves by entering a hiccup current limit 
mode. The modules will operate normally 
once the output current returns to the 
specified operating range. A latched over-
current protection option is also available. 
Consult the TDK Innoveta technical support 
for details. 
Output Over-Voltage Protection: The 
power modules have a control circuit, 
independent of the main control loop, that 
reduces the risk of over voltage appearing at 
the output of the power module during a 
fault condition. If there is a fault in the main 
regulation loop, the over voltage protection 
circuitry will latch the power module off once 
it detects the output voltage condition as 
specified on the Electrical Data page. To 
remove the module from the latched 
condition, either cycle the input power or 
toggle the remote ON/OFF pin providing that 
over-voltage conditions have been removed. 
The reset time of the ON/OFF pin should be 
500ms or longer. 
An optional non-latching OVP protection 
feature is also available. Consult the TDK 
Innoveta technical support for details. 
Thermal Protection: When the power 
modules exceed the maximum operating 
temperature, the modules will turn-off to 
safeguard the units against thermal damage. 
The module will auto restart as the unit is 
cooled below the over temperature 
threshold. A latched over-temperature 
protection option is also available. Consult 
the TDK Innoveta technical support for 
details. 
Remote On/Off: - The power modules have 
an internal remote on/off circuit. The user 
must supply an open-collector or compatible 
switch between the Vin(-) pin and the on/off 
pin. The maximum voltage generated by 
the power module at the on/off terminal is 
15V. The maximum allowable leakage 
current of the switch is 50uA. The switch 
must be capable of maintaining a low signal 
Von/off < 0.8V while sinking 400uA. 
The standard on/off logic is negative logic. 
The module will turn on if pin 2 is connected 
to pin 3, and it will be off if pin 2 is left open. 
If the negative logic feature is not being 
used, pin 2 should be shorted to pin 3. 
An optional positive logic is available. The 
power module will turn on if pin 2 is left open 
and will be off if pin 2 is connected to pin 3. 
If the positive logic circuit is not being used, 
terminal 2 should be left open. 
Vin(-)
On/ Off
Vin (+)
On/Off Circuit for positive or negative logic 
Output Voltage Adjustment: 
Not applicable for this product code. 
Remote Sense: 
Not applicable for this product code. 