Datasheet
Key Market Segments & Applications
Telecom/Datcom
Datacom
Process Control
Wireless Network
Measurement & Test
iBD Series
1
iBD Series
7A point of load converter
Key Market Segments & Applications
Telecom/Datcom
Datacom
Process Control
Wireless Network
Measurement & Test
•
Standard SIP Footprint (DOSA)
• 6.0-14VDC Input
• 0.8 - 5.5V Outputs
• Through Hole Mounting
• Low 12.7mm Profile
•
Non Isolated Output
iBD Features and Benefits
Features Benefits
• High operating efficiency (up to 92%) • Reduced system heating
• Constant 240kHz switching frequency • Easier system filtering
• Starts with pre-biased output • Supports complex digital systems
Specifications
MODEL iBD
ITEMS
Nominal Output Voltage VDC 0.8 - 5.5V
Input Voltage Range VDC 6 - 14V
Input Current (max) A 7A
Output Voltage Tolerance % ±3.5
Ripple & Noise (max) (pk - pk) mV 125
Line Regulation (max) % 0.2%
Load Regulation (typical) mV 20
Overload Protection A Inception- 11.5A; Short circuit - auto recovery
Overvoltage Protection - N/A
Remote Sense - Yes
Remote On / Off - Positive Logic standard. Negative logic available, see detailed datasheet
Sequencing - Yes
Temperature (operating) °C -40 to 105 (See detailed datasheet for derating)
Temperature (storage) °C -55 to 125
Humidity (operating) %RH 20-95 Non condensing
Humidity (storage) %RH 10-95 Non condensing
Cooling - Convection or forced air (See detailed datasheet for derating)
Isolation Voltage - None
Vibration (non operating) - 5 to 50Hz@0.5g(4.9m/s
2
), & 50 to 500Hz@1.5g(14.7m/s
2
) per Bellcore TR-EOP-000063-5.4.4
Shock - 196.1m/s
2
Safety Agency Certifications - Pending - UL60950 (US and Canada), VDE0805 (IEC60950), CB scheme (IEC60950)
Weight (max) g6
Size (LxWxH) mm 25.4 x 8.51 x 12.7
Warranty yrs 3 Years