Datasheet
1861-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
iAD Series
Features
u Standard SIP Footprint
u 6.0-14VDC Input
u 0.8-5.5V Outputs
u Through Hole Mounting
u High operating effi ciency (up to 94%)
u Constant switching frequency
u Starts with pre-biased output
16A Non-isolated Point of Load
Note: See website for detailed specifi cations and test methods
  Model    iAD
  Nominal Output Voltage  VDC  0.8 - 5.5V
  Input Voltage Range  VDC  6 - 14V
  Input Current (max)  A  18A
  Output Voltage Tolerance  VDC  N/A
  Ripple & Noise (max) (pk-pk)  mV  100
  Line Regulation (max)  mV  15
  Load Regulation (max)  mV  22
  Overload Protection  %  Inception - 28A; Short circuit - auto recovery
  Overvoltage Protection  -  N/A
  Remote Sense  -  Yes
  Remote On / Off  -  Positive or Negative Logic available, see Model Selector
  Sequencing  -  Yes
  Temperature (operating)  °C  -40 to 125
  Temperature (storage)  °C  -55 to 125
  Humidity (operating)  -  20-95% RH Non condensing
  Humidity (storage)  -  10-95% RH Non condensing
  Cooling  -  Convection or forced air
  Isolation Voltage  -  none
  Vibration (non-operating)  -  5 to 50Hz@0.5g (4.9m/s
2
), & 50 to 500Hz@1.5g (14.7m/s
2
) per Bellcore TR-EOP-000063-5.4.4
  Shock  -  196.1m/s
2
  Safety Agency Certifi cations  -  UL60950 (US and Canada), VDE0805 (IEC60950), CB scheme (IEC60950)
  Weight (max)  g  12
  Size (LxWxH)  mm  50.8 x 7.9 x 14
  Warranty  -  3 Years
Specifi cations
Key Market Segments & Applications