Datasheet
HWS-/HD Series
1
HWS-/HD Series
Single Output Industrial
Power Supplies
Key Market Segments & Applications
•
Limited Lifetime Warranty
• -10°C to +71°C Operation (-40°C start up)
• Universal Input (85 - 265VAC)
• Conformally coated PCB’s
• RoHS Compliant Design
HWS-/HD Features and Benefits
Features Benefits
• Limited Lifetime Warranty • Lower Cost of Ownership
• Conformally coated PCB’s • Operates in Harsh Environments
• Wide Range AC Input • Supports Global Use
Specifications
Industrial
Test
Broadcast
Comm
LED
Cots
www.emea.tdk-lambda.com/hws-hd
MODELS HWS30A HWS100A HWS300 HWS600 HWS1000 HWS1500
ITEMS HWS50A HWS150A
Input Voltage range (4) 85 - 265VAC (47-63Hz) or 120 - 370VDC 85 - 265VAC (47-63Hz) or 120 - 330VDC
Input Current (Typ) (1) A 0.65 / 0.4 1.3 / 0.65 4.1 / 2.1 8.1 / 3.9 13.5 / 7.0 19 / 10
- 0.7 / 0.35 1.9 / 0.95
Inrush Current (1) A 14 / 28 20 / 40
Power Factor - Meets EN61000-3-2
Temperature Coefficient - <0.02%/°C
Overcurrent Protection - >104%
Overvoltage Protection V Yes (See table on page 2)
Hold Up Time (Typ) ms 20
Leakage Current (60Hz) mA <0.5mA <0.75mA <1.2mA <
1.5mA
Remote Sense - No Yes
Indicator - Green LED = ON
Remote On/Off - No Yes (Isolated from output)
Parallel operation - No Single wire connection (5 units max)
DC Good - No Yes
Remote Adjust (PV) - No Yes (3)
Operating Temperature HWS30-150: -10°C to +71°C,
(derating applies above 50°C please refer to individual model specification for derating graph)
& Derating HWS300-1500: -10°C to +71°C, (-10 to +50°C: 100%, derate linearly to 50% load from +50 to +71°C)
Guaranteed start up at -40°C (see specification sheets on website for details and derating)
Storage Temperature -40°C to +85°C
Humidity (non condensing) - Operating: 30-90%RH (10 - 90% on HWS300-1500), Non operating 10-95%RH
Cooling - Convection Internal fan
Withstand Voltage (2) - Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance - >100MΩ at 25°C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/off 100VDC
Vibration (non operating) - MIL-STD-810F 514.5 Category 4, 10
Shock (in packaging) - MIL-STD-810F 516.5 Procedure I, VI (<196.1m/s
2
)
Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
Line Dip - Complies with SEMI F47 (200VAC line only)
Conducted & Radiated EMI - EN55011 / EN55022-B, FCC-B, VCCI-B (Curve A for HWS1500)
Immunity - IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2
Weight (Typ) g
200 420 1000 1600 3200 3800
260 470
Size (WxHxD) with cover mm
31.5 x 82 x 95 33 x 82 x 160 61 X 82 X 165 100 X 82 X 165 126.5 X 82 X 240 126.5 X 82 X 280
31.5 x 82 x 120 42 x 82 x 160
8,169,868 2,963,512 2,145,809 1,998,996 1,087,031 1,152,309
MTBF (5) hrs
3,726,622 2,676,081
Warranty - Limited Lifetime Warranty (See TDK-Lambda terms & conditions)
Notes: (1) 100/200VAC input. (2) HWS300-600 2.5kVAC Input to ground. (3) 1-6V program voltage input to adjust output 20-120% (typical) of nominal. See instruction for details & models with this feature.