Datasheet
TDK-Lambda
HWS100A/HD
SPECIFICATIONS
A258-01-01/HD
MODEL
ITEMS
1
Nominal Output Voltage
V
2
Maximum Output Current
A
3
Maximum Output Power
W
4
Efficiency (Typ.) (*1)
100VAC
%
200VAC
%
5
Input Voltage Range
(*2)
-
85 - 265VAC (47 - 63Hz) or 120 - 370VDC
6
Input Current (Typ.)
(*1)
A
0.9/0.45
1.3/0.65
7
Inrush Current (Typ.)
(*1)(*3)
-
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
8
PFHC
-
Designed to meet IEC61000-3-2
9
Power Factor (Typ.)
(*1)
-
10
Output Voltage Range
V
2.97 - 3.96
4.0 - 6.0
19.2 - 28.8
38.4 - 52.8
11
Maximum Ripple & Noise
0<Ta<71°C
mV
120
120
150
200
(*4)
-10<Ta<0°C
mV
160
160
180
240
12
Maximum Line Regulation
(*5)
mV
20
20
96
192
13
Maximum Load Regulation
(*6)
mV
40
40
150
240
14
Temperature Coefficient
-
Less than 0.02% / °C
15
Over Current Protection
(*7)
A
16
Over Voltage Protection
(*8)
V
4.13 - 4.95
6.25 - 7.25
18.8 - 21.8
30.0 - 34.8
55.2 - 64.8
17
Hold-up Time (Typ.)
(*1)
-
20ms
18
Leakage Current
(*9)
-
Less than 0.5mA. 0.2mA (Typ) at 100VAC / 0.4mA (Typ) at 230VAC
19
Remote Sensing
-
Possible
20
Parallel Operation
-
-
21
Series Operation
-
Possible
22
Operating Temperature
(*10)
-
-10 to +71°C (-10 to +50°C:100%, +60°C:65%, +71°C:30%)
Guarantee Start up at -40 to -10°C
23
Operating Humidity
-
30 to 90%RH (No Condensing)
24
Storage Temperature
-
-40 to +85°C
25
Storage Humidity
-
10 to 95%RH (No Condensing)
26
Cooling
-
Convection Cooling
27
Withstand Voltage
-
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (20mA) for 1min
28
Isolation Resistance
-
More than 100M
W
at 25
°
C and 70%RH Output - FG : 500VDC
29 Vibration (*11) - At no operating, 10 - 55Hz (Sweep for 1min) 19.6m/s
2
Constant, X,Y,Z 1hour each.
Designed to meet MIL-STD-810F 514.5 Category 4, 10
30
Shock
-
Less than 196.1m/s
2
Designed to meet MIL-STD-810F 516.5 Procedure I, VI
31
Safety
-
Approved by UL60950-1, CSA60950-1, EN60950-1.
Designed to meet Den-an Appendix 8 at 100VAC only.
32
Line DIP
-
Designed to meet SEMI-F47 (200VAC Line only)
33
Conducted Emission
(*12)
-
Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
34
Radiated Emission
(*12)
-
Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
35
Immunity
(*12)
-
Designed to meet IEC61000-6-2 IEC61000-4-2, -3, -4, -5, -6, -8, -11
36
Weight (Typ)
-
420g
37
Size (W x H x D)
mm
28 x 82 x 160 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1.
At 100VAC/200VAC, Ta=25°C, nominal output voltage and maximum output power.
*2.
For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 240VAC(50 - 60Hz).
*3.
Not applicable for the inrush current to Noise Filter for less than 0.2ms.
*4.
Measure with JEITA RC-9131B probe, Bandwidth of scope :100MHz.
*5.
85 - 265VAC, constant load.
*6.
No load-Full load, constant input voltage.
*7.
Constant current limit and Hiccup with automatic recovery. Avoid to operate at over load or short circuit condition.
*8.
OVP circuit will shut down output, manual reset (Re power on).
*9.
Measured by the each measuring method of UL, CSA, EN and Den-an (at 60Hz), Ta=25°C.
*10.
Output Derating
- Derating at standard mounting. Refer to OUTPUT DERATING CURVE (A258-01-02/HD-_).
- Load (%) is percent of maximum output power or maximum output current, do not exceed its derating of maximum load.
- For conditions of start up at -40°C to -10°C, refer to derating curve (A258-01-03/HD-_).
*11. Category 4 exposure levels : Track transportation over U.S. highways, Composite two-wheeled trailer.
*12. The power supply is considered a component which will be installed into a final equipment.
The final equipment should be re-evaluated that it meets EMC directives.
21.0 < 21.0 < 4.72 < 2.20 <8.92 <
15.0 - 17.4
150
180
48
96
87
180
60
89
150
8882 84 86 86
108.0 100.8
48
7 4.5
66.0 100.0 102.0 105.0
HWS100A
-48/HD
12 15
2.1
HWS100A
-5/HD
HWS100A
-12/HD
HWS100A
-15/HD
HWS100A
-24/HD
245
0.96/0.89 0.98/0.93
120
7.35 <
12.0 - 18.09.6 - 14.4
9084 86 88 88
HWS100A
-3/HD
20 20 8.5
3.3