4-6. Low Output Detection Circuit (DC_OK) 
Low output voltage detection circuit is provided. DC okay (DC_OK) signal will turn “High” level to indicate abnormal 
status  when  the  output  voltage  becomes  less  than  approximately  80%  of  rated  value  caused  by  either  the  drop  or 
brownout of the input voltage or OCP, OVP and OTP function generation. It uses the open collector method as shown 
below 
4-7. Remote ON/OFF Control 
Remote ON/OFF control is provided. 
Using this function, output on/off is allowed to be controlled without input voltage on/off. The output is turned ON when 
CNT+  and  CNT-  terminals  are  shorted,  while  the  output  is  turned  OFF  when  these  terminals  are  opened.  When  this 
function is not used, connect CNT+ and CNT- terminals together. The standards for this function are as follows 
(1) TTL compatible. 
(2) The maximum input voltage to CNT+ terminal is 12V, and the maximum allowable reverse voltage is -1V. 
(3) The sink current for CNT+ terminal is 3.5mA. 
(4) A switch or a relay or a transistor or a FET can be used as ON/OFF switch. 
The /RL option model reverses the logic of the remote ON/OFF function. 
Output Status 
Voltage Range between CNT+ and CNT- 
Standard type  /RL option 
2.4 ≤ H ≤ 12.0V or Open  OFF  ON 
0.0 ≤ L ≤ 0.8V or Short  ON  OFF 
Relay, Transistor, 
FET, Switch 