Data Sheet
General Specifications Genesys™ GENH750W
Also available, Genesys™
1U full Rack 750W/1500W/2400W
2U full Rack 3300W/5000W
2.1 INPUT CHARACTERISTICS
1. Input voltage/freq. (*1) 85~265Vac continuous, 47~63Hz, single phase
2. Power Factor 0.99 @100/200Vac, rated output power.
3. EN61000-3-2,3 compliance Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power.
4. Input current 100/200Vac 750W :10.5A / 5A,
5. Inrush current 100/200Vac 750W :Less than 25A,
6. Hold-up time More than 20mS, 100Vac, at 100% load.
2.2 POWER SUPPLY CONFIGURATION
1. Parallel Operation Up to 4 units in master/slave mode with single wire current balance connection
2. Series Operation Up to 2 units. with external diodes. 600V Max to Chassis ground
2.3 ENVIRONMENTAL CONDITIONS
1. Operating temp 0~50°C, 100% load.
2. Storage temp -20~70°C
3. Operating humidity 30~90% RH (non-condensing).
4. Storage humidity 10~95% RH (non-condensing).
5. Vibration MIL-810E, method 514.4, test cond. I-3.3.1. The EUT is fixed to the vibrating surface.
6. Shock Less than 20G, half sine, 11mSec. Unit is unpacked.
7. Altitude Operating: 10000ft (3000m), Derat output current by 2%/100m above 2000m, Non operating: 40000ft (12000m).
2.4 EMC
1. Applicable Standards:
2. ESD IEC1000-4-2. Air-disch. -8KV, contact disch. -4KV
3. Fast transients IEC1000-4-4. 2KV
4. Surge immunity IEC1000-4-5. 1KV line to line, 2KV line to ground
5. Conducted immunity IEC1000-4-6, 3V
6. Radiated immunity IEC1000-4-3, 3V/m
7. Conducted emission EN55022B, FCC part 15J-B, VCCI-B.
8. Radiated emission EN55022A, FCC part 15-A, VCCI-A.
9. Voltage dips EN61000-4-11
10. Conducted emission EN55022B, FCC part 15-B, VCCI-B.
11. Radiated emission EN55022A, FCC part 15-A, VCCI-A.
2.5 SAFETY
1.Applicable standards: UL 60950-1, CSA22.2 No.60950-1, IEC 60950-1, EN 60950-1
2.Interface classification
Models with Vout 50V: Output is SELV, all communication/control interfaces (RS232/485, IEEE, Isolated Analog,
LAN, Sense, Remote Programming and Monitoring) are SELV.
Models with 60V Vout 400V: Output is Hazardous, communication/control interfaces: RS232/485, IEEE,
Isolated Analog, LAN, Remote Programing and Monitoring (pins 1-3, pins14-16) are SELV, Sense, Remote
Programming and Monitoring (pins 8-13, pins 21-25) are Hazardous.
Models with 400V Vout 600V: Output is Hazardous, all communication/control interfaces (RS232/485, IEEE,
Isolated Analog, LAN, Sense, Remote Programming and Monitoring) are Hazardous.
3.Withstand voltage
Vout 50V models : Input-Output (SELV): 4242VDC 1min, Input-communication/control (SELV): 4242VDC 1min,
Input-Ground: 2828VDC 1min,
60V Vout 150V models: Input-Output (Hazardous): 3425VDC 1min, Input-communication/control (SELV):
4242VDC 1min, Output(Hazardous)-SELV: 2307VDC 1min, Output(Hazardous)-Ground: 1414VDC 1min,
Input-Ground: 2828VDC 1min.
300V Vout 600V models: Input-Output(Hazardous): 3490VDC 1min, Input-communication/control (SELV):
4242VDC 1min, Hazardous. Output-communication/control(SELV): 4242VDC 1min,
Output(Hazardous)-Ground: 2738VDC 1min, Input-Ground: 2828VDC 1min.
4.Insulation resistance More than 100Mohm at 25°C , 70% RH.
2.6 MECHANICAL CONSTRUCTION
1. Cooling Forced air flow: from front to rear. No ventilation holes at the top or bottom of the chassis; Variable fan speed.
2. Dimensions (WxHxD) W: 214.0mm, H: 43.6mm, (57.0mm Benchtop version), D: 437.5mm (excluding connectors, encoders, handles, etc.)
3. Weight 7Kg (15 Lbs)
4. AC Input connector IEC320 AC Inlet.
5. Output connectors 6V to 60V models: Bus-bars (hole Ø 6.5mm). 80V to 600V models: Meating plug, Phoenix P/N: GIC 2.5/4-ST-7.62.
2.7 RELIABILITY SPECS
1. Warranty 5 years.
GENH | GENESYS™ | 5