Data Sheet

Worldwide Safety Agency Approvals; CE
Mark for LVD and EMC Regulation
Genesys™ GENH750W-1U
The Genesys™ family of programmable power supplies sets a new standard for flexible, reliable,
AC/DC power systems in OEM, Industrial and Laboratory applications.
Features include:
Front Panel Description
High Power Density available:
750W in 1U half-rack size.
Wide Range Input (85 - 265Vac Continuous)
Active Power Factor Correction (0.99 typical)
Output Voltage up to 600V, Current up to 100A
Built-in RS-232/RS-485 Interface
Front Panel Lockout
Last-Setting Memory
High Resolution 16 bit ADCs & DACs
Reliable Encoders for Voltage and Current Adjustment
Constant Voltage/Constant Current auto-crossover
• Advanced Parallel reports total current up to four
identical units
Global Commands for Serial RS-232/RS-485 Interface
Independent Remote ON/OFF
and Remote Enable/Disable
External Analog Programming and Monitoring
Reliable Modular and SMT Design
19" Rack Mounted ATE benchtop and OEM applications
Side-by-side mounting of two units in a 19” rack
Optional Interfaces
Isolated Analog Programming and Monitoring
Interface (0-5V/0-10V & 4-20mA)
IEEE 488.2 SCPI (GPIB) Multi-Drop
Compliant LAN
LabView® and LabWindows® drivers
Five Year Warranty
1. AC ON/OFF Switch
2. Air Intake allows zero stacking for maximum system flexibility and power density.
3. Reliable encoder controls Output Voltage and sets Address.
4. Volt Display shows Output Voltage and directly displays OVP, UVL and Address settings.
5. Reliable encoder controls Output Current, sets baudrate and Advanced Parallel mode.
6. Current Display shows Output Current and displays baudrate.
7. Function/Status LEDs:
Alarm
Fine Control
Preview Settings
Foldback Mode
Remote Mode
Output On
8. Pushbuttons allow flexible user configuration
Coarse and Fine adjustment of Output Voltage/Current and Advanced Parallel Master or Slave
Preview settings and set Voltage/Current with Output OFF, Front Panel Lockout
Set OVP and UVL Limits
Set Current Foldback
Local/Remote Mode and select Address and Baudrate
Output ON/OFF and Auto-Start/Safe-Start Mode
2 | GENESYS | GENH