Data Sheet

Genesys™ Power Parallel and Series Configurations
Parallel operation - Master/ Slave:
Active current sharing allows up to 4 units to be connected in an
auto-parallel configuration for four times the output power.
Series operation
Up to two units may be connected in series to increase the output
voltage or to provide bipolar output. (Max 600V to Chassis Ground).
Remote Programming via RS-232 & RS-485 Interface
Standard Serial Interface allows chain control of up to 31 power
supplies on the same bus with built-in RS-232 & RS-485 Interface.
Programming Options (Factory installed)
Digital Programming via IEEE Interface P/N: IEEE
IEEE 488.2 SCPI Compliant
Program Voltage Program Current
Measure Voltage Measure Current
Over Voltage setting and shutdown Current Foldback shutdown
Software Calibration Error and Status Messages
Isolated Analog Programming
Four Channels to Program and Monitor Voltage and Current.
Isolation allows operation with floating references in difficult electrical environments.
Choose between programming with Voltage or Current.
Connection via removable terminal block: Phoenix MC1,5/8-ST-3.81.
P/N: IS510 - Voltage Programming, user-selectable 0-5V or 0-10V signal.
Power supply Voltage and Current Programming accuracy +/-1%
Power supply Voltage and Current Monitoring accuracy +/-1.5%
P/N: IS420 - Current Programming with 4-20mA signal.
Power supply Voltage and Current Programming accuracy +/-1%
Power supply Voltage and Current Monitoring accuracy +/-1.5%
Genesys™
750W/1500W-1U