2.1 INPUT CHARACTERISTICS
2.7 MECHANICAL CONSTRUCTION
1. Cooling
2. Dimensions (WxHxD) W: 423mm, H: 43.6mm, D: 432.8mm (excluding connectors, encoders, handles, etc.)
3. Weight
10 kg.
4. AC Input connector (with Protective Cover)
5.Output connectors
8V to 100V models: Bus-bars (hole Ø 8.5mm ). 150V to 600V models:
wire clamp connector
, Phoenix P/N: FRONT-4-H-7.62
Forced air flow: from front to rear. No ventilation holes at the top or bottom of the chassis; Variable fan speed.
2.8 RELIABILITY SPECS
1. Warranty 5 years.
1. Parallel Operation
2. Series Operation
Up to 4 identical units in master/slave mode
Up to 2 identical units. with external diodes. 600V Max to Chassis ground
2.3 POWER SUPPLY CONFIGURATION
2.4 ENVIRONMENTAL CONDITIONS
1. Operating temp
2. Storage temp
-20~85°C
3. Operating humidity
20~90% RH (non-condensing).
4. Storage humidity
10~95% RH (non-condensing).
5. Vibration
MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface.
6. Shock
Less than 20G , half sine , 11mSec. Unit is unpacked.
7. Altitude
Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp.
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m).
0~50°C, 100% load.
EN55022A, FCC part 15-A, VCCI-A.
2.5 EMC
1.Applicable Standards:
2.ESD
IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV
3.Fast transients
IEC1000-4-4. 2KV
4.Surge immunity
IEC1000-4-5. 1KV line to line, 2KV line to ground
5.Conducted immunity
IEC1000-4-6, 3V
6.Radiated immunity
IEC1000-4-3, 3V/m
7.Magnetic field immunity
EN61000-4-8, 1A/m
8.Voltage dips
EN61000-4-11
9.Conducted emission
10. Radiated emission
EN55022A, FCC part 15-A, VCCI-A.
More than 100Mohm at 25°C , 70% RH.
2.6 SAFETY
1.Applicable standards:
400<Vout≤600V:Output is hazardous, IEEE/Isolated analog are not SELV.
2.Withstand voltage
40<Vout≤100V models: Input-Haz. Output: 2600VDC 1min, Input-SELV: 4242VDC 1min.
Hazardous Output.-SELV: 1900VDC 1min, Hazardous Output-Ground:1200VDC 1min. Input-Ground: 2828VDC 1min.
3.Insulation resistance
CE Mark, UL60950,EN60950 listed. Vout≤40V:Output is SELV , IEEE/Isolated analog are SELV.
40<Vout≤400V: Output is hazardous, IEEE/Isolated analog are SELV.
Vout≤40V models :Input-Outputs (SELV): 4242VDC 1min, Input-Ground: 2828VDC 1min.
1. Input voltage/freq. (*3)
3. Power Factor (Typ)
4. Efficiency (*4)
10mSec for Single-Phase and 3-phase 208V models. Rated output power.
5. Inrush Current (*5)
6. Hold-up time (Typ)
Single Phase,230V models: 170~265Vac, 47~63Hz
3-Phase, 208V models: 170~265Vac, 47~63Hz
2. Maximum Input
current at 100% load
Single Phase,230V models:
3-Phase, 208V models:
A
Single-Phase and 3-Phase 208V models: Less than 50A
mS
17
10.5
GEN
8-300 10-240 16-150 20-120 30-80 40-60 600-4300-8150-16100-2480-3060-40
17
10.5
17
10.5
16.3
9.8
16.3
9.8
16.3
9.8
16.3
9.8
16.3
9.8
16.3
9.8
16.3
9.8
16.3
9.8
16.3
9.8
Single Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208 Vac, rated output power.
%
84 84 84 86 86 88 88 88 88 88 88 88
8. RoHS Compliance
Complies with the requirements of RoHS directive.
100<Vout≤600V models: Input-Haz. Output: 4000VDC 1min, Input-SELV: 4242VDC 1min.
Hazardous Output.-SELV: 3550VDC 1min. Hazardous Output-Ground:2670VDC 1min. Input-Ground: 2828VDC 1min.
A
VAC
Single Phase,230V models,
wire clamp connector
, Phoenix P/N: FRONT-4-H-7.62, with Strain relief.
3-Phase, 208V models,
wire clamp connector
, Phoenix P/N: FRONT-4-H-7.62, with Strain relief.
Outline Drawing Genesys™ 2.4kW Units
|4
NOTE
Auxiliary autput Header: IMC 1.5/7-G-3.81, Plug: IMC 1.5/7-ST-3.81 (Phoenix Contact).
1. 15V output
2. 5V output
15V
±5%, 0.2A Max load, Ripple & Noise 50mVp-p. Referenced internally to the negative output potential.
5V
±5%, 0.2A Max load, Ripple & Noise 50mVp-p. Referenced internally to IF_com potential.
2.2 AUXILIARY OUTPUT